€ 31.79

CNOR PRACTICE TEST NEWEST 2024 ACTUAL EXAM TEST BANK COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS)

CNOR PRACTICE TEST NEWEST 2024  ACTUAL EXAM TEST BANK COMPLETE  QUESTIONS AND CORRECT DETAILED  ANSWERS (VERIFIED ANSWERS)

Peracetic acid - ANSWERS,Automated Endoscope Reprocessor (AER) - GI
For items that can be immersed
Corrosive to instruments and people
Temp 120-130 degrees F
20-30 mins
Micro filtered tap water rinses x 4 to turn it back to vinegar
Must have log
Sterilizes using acidity
Vinegar with extra hydrogen to make it very acidic
Ozone - ANSWERS,low temp sterilization
only one manufacturer in the USA
FDA has cleared ozone for sterilization of metal and plastic
Exhaust is passed through a catalytic converter
Environmentally sound
No aeration
By-products are oxygen and water
Dry heat - ANSWERS,High temp
Best for heat stable powder and oils
Dental instruments, burrs, reusable needles, glassware
Don't use tape
Common in doctor and dental offices and tattoo parlors
360-400 degrees F
50-60 min run time
Specific packaging for this
QC - ANSWERS,items should be traceable from method of sterilization
Lot, control, load or cycle, date, and time should be documented for each item
Required by CDC to track SSIs on certain patients like colons and totals
Autoclave QC - ANSWERS,Daily biological (ideally) for gravity displacement and pre-vac
Daily Bowie-Dick for pre-vac (1st run is warm up, 2nd run is test, 3rd run is item); uniform pattern
indicates that the vac cycle functioned properly
Done with every implant
Sterilization log required
Steam - gravity displacement and prevac testing - ANSWERS,Geobacillus stearothemophilus spore
testing at least weekly and preferably daily
Pre-vac testing - ANSWERS,Air removal like Bowie-Dick should be done daily in an empty chamber;
for new, renovated, or moved equipment, 3 consecutive successful air removal tests should be done
before the biological
Ethylene oxide testing - ANSWERS,Bacillus atropheus spore testing done with every load
Plasma testing - ANSWERS,Geobacillus stearothermophilus spore testing done at same interval as
other sterilizers in the facility
Ozone and peracetic acid testing - ANSWERS,Geobacillus stearothermophilus daily
Dry heat testing - ANSWERS,Bacillus atropheus indicators upon installation and after any repair
(table top type monitored weekly)
Packaging Sterile Items - ANSWERS,Must work with the type of sterilization
Must allow for identification of the contents (writing on the outside)
Weight should not exceed 25 lbs
Lint free
Free of holes
Sterile storage areas must not exceed 78 degrees F or 60% humidity
Manufacturer's instructions always supersede the guidelines
Packaging and Sterilization - ANSWERS,No textiles, peel pouches, or rubber mats inside the tray
Instruments disassembled
Instruments in open, unlocked position
Integrator in corner of tray because that's the hardest for steam to get to
Indicator on inside and outside of tray (class 5 indicator inside)
Count sheet on outside of trays
Inside of sealed envelope is not sterile
Integrator on top of tray
Peel Pouches - ANSWERS,Not stacked inside of sterilization chamber
Write on the plastic, not paper
Not for use with heavy items
steam only goes through paper side
Double pouching - ANSWERS,with manufacturer's instructions onl

Preview document (3 van de 52 pagina's)

Unlock document

Download alle 52 pagina's voor € 31,79

Document in winkelwagen
Document rapporteren Document rapporteren

Voordelen van Knoowy

€ 31,79

Document in winkelwagen
  • check Niet tevreden? Geld terug
  • check Document direct te downloaden
  • check € 0,50 korting bij betalen met saldo
  • check Ontvang gratis oefenvragen bij document

Specificaties

Verkoper

philomath

278 documenten geüpload

23 documenten verkocht


Experienced tutor dedicated to personalized learning. I adapt to students' needs, foster open communication, and inspire a love for learning

Verdienen aan je samenvattingen?

icon 2

Maak je zelf samenvattingen of heb je nog uitgewerkte opdrachten liggen? Upload je documenten dan op Knoowy en verdien geld.

Document uploaden

Al meer dan 146.000 tevreden studenten

  • Isabelchloe
    Isabelchloe

    Knoowy is een top site waar je veel samenvattingen op kan vinden.

  • Petra    van Berghe
    Petra van Berghe

    Ik vind Knoowy erg handig om samenvattingen van mijn opleiding te kopen.

  • MathieuHaldermans
    MathieuHaldermans

    Als student voor de examencommissie besparen samenvattingen mij een heleboel opzoekwerk!

  • melissadesmet
    melissadesmet

    Zeer goed in gebruik en betrouwbaar. Zelf zou ik er ook samenvattingen op plaatsen.

  • noellebeekhoven
    noellebeekhoven

    Knoowy heeft mij geholpen om aan samenvattingen te komen, zodat ik tijd bespaar door het zelf niet te hoeven maken.

  • Robin33
    Robin33

    Snel, betrouwbaar, veel aanbod van samenvattingen. Goed en duidelijk weergegeven.

  • FranCeulemans
    FranCeulemans

    Handige bron om samenvattingen te vinden, vorige beoordelingen helpen hier zeker bij!

  • larbi
    larbi

    Een goede keuze voor samenvattingen. Je bespaart tijd en energie.

Inloggen via e-mail
Nieuw wachtwoord aanvragen
Registreren via e-mail
Winkelwagen
  • loader

Actie: ontvang 10% korting bij aankoop van 3 of meer items! Actie: ontvang 10% korting bij aankoop van 3 of meer items!

Actie: ontvang 10% korting bij aankoop van 3 of meer items!

loader

Ontvang gratis €2,50 bij je eerste upload

Help andere studenten door je eigen samenvattingen te uploaden op Knoowy. Upload ten minste één document en krijg gratis € 2,50 tegoed.

Upload je eerst document