- Je bekeek:CNOR PRACTICE TEST NEWEST 2024 ACTUAL EXAM TEST BANK COMPLETE QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS)
- Geüpload door:nyawiraalex
- Studie: Chamberlain College Of Nursing / NURSING / Peracetic acid - ANSWERS,Automated Endoscope Reprocessor (AER) - GI For items that can be immersed Corrosive to instruments and people Temp 120-130 degrees F 20-30 mins Micro filtered tap water rinses x 4 to turn it back to vinegar Must have log Sterilizes using acidity Vinegar with extra hydrogen to make it very acidic Ozone - ANSWERS,low temp sterilization only one manufacturer in the USA FDA has cleared ozone for sterilization of metal and plastic Exhaust is passed through a catalytic converter Environmentally sound No aeration By-products are oxygen and water Dry heat - ANSWERS,High temp Best for heat stable powder and oils Dental instruments, burrs, reusable needles, glassware Don&039;t use tape Common in doctor and dental offices and tattoo parlors 360-400 degrees F 50-60 min run time Specific packaging for this QC - ANSWERS,items should be traceable from method of sterilization Lot, control, load or cycle, date, and time should be documented for each item Required by CDC to track SSIs on certain patients like colons and totals Autoclave QC - ANSWERS,Daily biological (ideally) for gravity displacement and pre-vac Daily Bowie-Dick for pre-vac (1st run is warm up, 2nd run is test, 3rd run is item); uniform pattern indicates that the vac cycle functioned properly Done with every implant Sterilization log required Steam - gravity displacement and prevac testing - ANSWERS,Geobacillus stearothemophilus spore testing at least weekly and preferably daily Pre-vac testing - ANSWERS,Air removal like Bowie-Dick should be done daily in an empty chamber; for new, renovated, or moved equipment, 3 consecutive successful air removal tests should be done before the biological Ethylene oxide testing - ANSWERS,Bacillus atropheus spore testing done with every load Plasma testing - ANSWERS,Geobacillus stearothermophilus spore testing done at same interval as other sterilizers in the facility Ozone and peracetic acid testing - ANSWERS,Geobacillus stearothermophilus daily Dry heat testing - ANSWERS,Bacillus atropheus indicators upon installation and after any repair (table top type monitored weekly) Packaging Sterile Items - ANSWERS,Must work with the type of sterilization Must allow for identification of the contents (writing on the outside) Weight should not exceed 25 lbs Lint free Free of holes Sterile storage areas must not exceed 78 degrees F or 60% humidity Manufacturer&039;s instructions always supersede the guidelines Packaging and Sterilization - ANSWERS,No textiles, peel pouches, or rubber mats inside the tray Instruments disassembled Instruments in open, unlocked position Integrator in corner of tray because that&039;s the hardest for steam to get to Indicator on inside and outside of tray (class 5 indicator inside) Count sheet on outside of trays Inside of sealed envelope is not sterile Integrator on top of tray Peel Pouches - ANSWERS,Not stacked inside of sterilization chamber Write on the plastic, not paper Not for use with heavy items steam only goes through paper side Double pouching - ANSWERS,with manufacturer&039;s instructions onl
- 52 pagina's