ARDMS SPI EXAM QUESTIONS AND
ANSWERS LATEST 2024
Which gain will increase the risk of bioeffects?
a. transmit
b. receive
c. gain
d. overall gain - ✔✔✔✔-a. transmit
Which of the following is considered the memory of an
ultrasound instrument?
a. pulser
b. transducer
c. receiver
d. beam former
e. digital scan converter
f. display monitor - ✔✔✔✔-e. digital scan converter
Spectral broadening suggest:
a. laminar flow
b. turbulent flow
c. flow away from the transducer
d. flow towards the transducer - ✔✔✔✔-b. turbulent flow
With pulse wave Doppler axial resolution: - ✔✔✔✔-degrades
What color is usually use in color flow Doppler variance map to
indicate turbulent flow? - ✔✔✔✔-green
Doppler high pass filter eliminates: - ✔✔✔✔-high amplitude
signals; low velocity flow
The Doppler wall filter is considered a: - ✔✔✔✔-high pass filter
The Nyquist Limit is equal to:
a. propagation speed x frequency
b. propagation speed/ wavelength
c. PRF/2
d. 4xV^2 - ✔✔✔✔-c. PRF/2
Multiple echoes, equally spaced originating from a gas bubble is
called:
a. comet tail
b. ring down
c. slice thickness artifact
d. multipath - ✔✔✔✔-b. ring down
An increase in red blood cell velocity will_____ the Doppler
Shift:
a. increase
b. decrease
c. not change
d. cannot be predicted - ✔✔✔✔-a. increase
The primary advantage of CW Doppler is:
a. range resolution
b. range discrimination
c. range ambiguity
d. range gating
e. absence of sampling rate - ✔✔✔✔-e. absence of sampling
rate
The range for ultrasound begins:
a. 20 Hz
b. 20,000 Hz
c. 2 MHz
d. 15 MHz - ✔✔✔✔-b. 20,000 Hz (useful frequency range for
clinical imaging is 2MHz-10MHz)
Which instrument control affects the amplitude (dB) of the
outgoing signal:
a. gain
b. receiver gain
c. TGC
d. transmit gain
e. overall gain - ✔✔✔✔-d. transmit gain; amplitude can be
affected by the sonographer
Which of the following is used to convert Doppler shift
information into color:
a. high PRF
b. fast Fourier transform
c. autocorrelation
d. time interval histogram - ✔✔✔✔-c. autocorrelation
b is incorrect because fast Fourier transform is the method used
to process conventional Doppler shift information but is too slow
a method for color Doppler
ati comprehensive comprehensive predictor computer science fundamentals health care health care / nursing health care/ nursing healthcare hesi hesi rn exit maternal newborn med surg medical nursing medical surgical mental health nurs nursing nursing & health nutrition pathophysiology pediatrics pharmacology test bank tncc
Knoowy is heel handig om te gebruiken. Zeker aan te raden.
De documenten zijn duidelijk en goed samengevat. Het is fijner leren dan vanuit het boek.
Prima service, snelle afhandeling. Ik ga hiervan gebruik maken gedurende mijn hele studie.
Snel, betrouwbaar, veel aanbod van samenvattingen. Goed en duidelijk weergegeven.
Soms koop ik meerdere samenvattingen over 1 boek. Dit helpt mij als ik onvoldoende tijd heb om het hele boek te lezen en zelf geen samenvatting kan maken.
Online kun je studenten helpen met notities en samenvattingen terwijl je niet meer echt naar je samenvatting hoeft om te kijken. Het past goed bij je studie en je kunt tegelijk wat bijverdienen!
Super handig als je weinig tijd hebt. Samenvattingen zijn makkelijk te vinden en keuze is groot.
Weer een goede ervaring met Knoowy. Makkelijk en snel een nette samenvatting.